INTEGRA 128 Plus EN50131 Grade 3 Compliant Alarm Control Panel Main Board, With 16 Up to 128 Zones and Outputs
Features:
| Programmable wired outputs | 16 |
| Users + Administrators | 240 + 8 |
| Maximum current consumption from the battery | 200 mA |
| Maximum battery charging current | 1.5 A |
| Power supply current efficiency (supplying devices + charging batteries) | 2000 + 1500 mA |
| Power supply output voltage | 10,5…14 V DC |
| Carrying capacity of the +KPD output (±10%) | 3 A |
| Carrying capacity of the +EX1 and +EX2 outputs (±10%) | 3 A |
| Programmable wired inputs | 16 |
| Maximum number of programmable inputs | 128 |
| Maximum current consumption from the 230V network | 400 mA |
| Maximum number of programmable outputs | 128 |
| Supplying outputs | 3 |
| Communication buses | 1 + 2 |
| Keypads | up to 8 |
| Extender circuits | up to 64 |
| Telephone numbers for notification (voice/PAGER + SMS) | 16 + 16 |
| Installer-defined text messaged | 64 |
| Security grade according to EN 50131 | Grade 3 |
| Supply voltage (±15%) | 20 V AC, 50-60 Hz |
| Low current programmable outputs rating | 50 mA |
| High current programmable outputs rating | 3 A |
| Event log | 22527 |
| Objects | 8 |
| Partitions | 32 |
| Timers | 64 |
| Board dimensions | 264 x 134 mm |
| Operating temperature range | -10…+55 °C |
| Voice messages | 32 |
| Weight | 320 g |
| Maximum humidity | 93±3% |
| Current consumption from battery – standby | 130 mA |
| Recommended transformer type | 75 VA |
| Battery failure voltage threshold (±10%) | 11 V |
| Battery cut-off voltage (±10%) | 10,5 V |
| Environmental class according to EN50130-5 | II |
| Current consumption from the 230V network in standby | 135 mA |
For more information: INTEGRA 128 Plus